Profoto Acute2 manual Guide de l'utilisateur Page 19

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 18
BatPac
19
www.profoto.com
Trouble shooting
Symptom Diagnose Action
No output voltage, Power
On Indicator [2] not
illuminated
Bad connection to the battery. Check the cable connection to the Sealed Lead
Acid Battery [19].
Internal fuses defect. Check Fuses [17]. If it still does not work after
replacing fuses, contact your nearest Profoto
service station.
No output voltage, Over
Temperature Indicator
[5] illuminated.
The BatPac has been
overheated.
Switch off the BatPac and the power
consuming unit(s).
Wait for approx. 5-10 minutes and switch
on the BatPac only (disconnect the power
consuming unit).
Reduce the loading and ensure better
ventilation.
If this is a frequently repeating problem it
may be a problem with the internal fan of the
BatPac. Contact your nearest Profoto service
station for guidance.
No output voltage,
Battery Low Indicator [3]
illuminated.
The GFCI has been activated. Potential safety hazard! Leave the BatPac and
the connected unit to your nearest Profoto
service station for check-up and repair.
Battery Low Indicator [3]
is illuminated.
Battery voltage is too low. The battery must be recharged.
The connected device
doesn’t work properly
or at all.
Energy consumption is too
high (more than 600W)
Disconnect the power consuming unit,
if possible use a unit with a lower power
consumption.
Vue de la page 18