BatPac
19
www.profoto.com
Trouble shooting
Symptom Diagnose Action
No output voltage, Power
On Indicator [2] not
illuminated
Bad connection to the battery. • Check the cable connection to the Sealed Lead
Acid Battery [19].
Internal fuses defect. • Check Fuses [17]. If it still does not work after
replacing fuses, contact your nearest Profoto
service station.
No output voltage, Over
Temperature Indicator
[5] illuminated.
The BatPac has been
overheated.
• Switch off the BatPac and the power
consuming unit(s).
• Wait for approx. 5-10 minutes and switch
on the BatPac only (disconnect the power
consuming unit).
• Reduce the loading and ensure better
ventilation.
• If this is a frequently repeating problem it
may be a problem with the internal fan of the
BatPac. Contact your nearest Profoto service
station for guidance.
No output voltage,
Battery Low Indicator [3]
illuminated.
The GFCI has been activated. • Potential safety hazard! Leave the BatPac and
the connected unit to your nearest Profoto
service station for check-up and repair.
Battery Low Indicator [3]
is illuminated.
Battery voltage is too low. • The battery must be recharged.
The connected device
doesn’t work properly
or at all.
Energy consumption is too
high (more than 600W)
• Disconnect the power consuming unit,
if possible use a unit with a lower power
consumption.
Commentaires sur ces manuels